Send Message
Lanry Instruments (Shanghai) Co., Ltd.

Lanry Instruments (Shanghai) Co., Ltd.

 

Specialize In Ultrasonic Flowmeter More Than 20 Years!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsInsertion Ultrasonic Flow Meter

TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range

TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range

  • TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range
TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range
Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-EI
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton Packing
Supply Ability: 100unit/week
Contact Now
Detailed Product Description
Product Name: Insertion Flow Meters Liquid Measurement Output: Datalogger/4-20mA /OCT /RS485/RS232/GPRS
Accuracy: Reading+/- 1% Transducer Range: DN20-DN6000
Application: Measuring Liquids Power Supply: 85`265VAC
High Light:

insertion type ultrasonic flow meter

,

digital ultrasonic flow meter

Insertion flow meters liquid measurement TF1100-EI transit time type
 
There are two main types of ultrasonic flowmeters – transit-time and Doppler. Insertion flow meters liquid measurment TF1100-EI  is a transit-time ultrasonic flowmeter, it has both a sender and a receiver. It sends two ultrasonic signals across a pipe at an angle – one with the flow and one against the flow. The meter then measures the “transit time” of each signal. When the ultrasonic signal travels with the flow, it travels faster than when it travels against the flow. The difference between the two transit times is proportional to flowrate.
Insertion flow meters liquid measurement TF1100-EI provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art technologies on ultrasonic transmission /receiving, digital signal processing and transit-time measurement. The proprietary signal quality tracking and self-adapting technologies allow system to optimally adapt to different pipe materials automatically. Due to hot-tapped mounting of insertion transducers, there is no ultrasonic compound and coupling problem; Even though the transducers are inserted into pipe wall, they do not intrude into the flow, thus, do not generate disturbance or pressure drop to the flow. The insertion (wetted) type has the advantage of long-term stability and better accuracy.
 
Insertion flow meters liquid measurement TF1100-EI transit time type Features:
 
1. Hot-tapped installation, no pipe line flow interrupted
2. Wide liquid temperature range: -35℃~200℃.
3. Data logger function for insertion ultrasonic flow meter
4. Thermal energy measurement capability can be optional.
5. For commonly used pipe materials and diameters from 20mm to over 6.0m.

6. Wide bi-directional flow range of 0.01 m/s to 12 m/s..

 

Application
 

General
● Service and maintenance

● Replacement of defective devices

● Support of commissioning process and installation

● Performance and efficiency measurement
- Evaluation and assessments
- Capacity measurement of pumps
- Monitoring of regulating valves

● Energy efficiency audits

 

Water and waste water industry - hot water, cooling water, potable water, sea water etc.)
Petrochemical industry
Chemical industry -chlorine, alcohol, acids, .thermal oils.etc
Refrigeration and air conditioning systems
Food , beverage and pharmaceutical industry

 

TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range 0

 

Specifications:Transmitter

 

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V DC: 24V/500mA
Enclosure type Wall-mounted
Degree of protection IP66 according to EN60529
Operating temperature -20℃ to +60℃
Housing material Fiberglass
Display 4 line×16 English letters LCD graphic display, backlit
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJ,KWh can be optional
Communication 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data
Security Keypad lockout, system lockout
Weight 2.4kg

 

Specifications:Transducer

 

Degree of protection IP67 or IP68 according to EN60529
Suited Liquid Temperature Std. Temp.: -35℃~85℃
High Temp.: -35℃~150℃
Pipe diameter range DN65-6000
Transducer Size Type S Φ58*199mm
Material of transducer Stainless Steel
Cable Length Std: 10m
Temperature Sensor

Pt1000, 0 to 200℃, Clamp-on and Insertion type Accuracy: ±0.1%

 

 

Packing & Delivery

 

Insertion flow meters liquid measurement TF1100-EI wall mounted transit time type

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range 1TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range 2TF1100-EI Insertion Type Ultrasonic Flow Meter Wide Liquid Temperature Range 3

Delivery

Insertion flow meters liquid measurement TF1100-EI wall mounted transit time type

Standard meter: 3-7 days

Special meter: pls contact us

Express, by air, by sea can be optional.

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)