Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter

Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter

Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter
video
Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter
Product Details:
Place of Origin: Shanghai, China (Mainland)
Brand Name: Lanry
Certification: CE
Model Number: TF1100-CH
Payment & Shipping Terms:
Minimum Order Quantity: 1 Unit
Price: Negotiable
Packaging Details: Carton package
Contact Now
Detailed Product Description
Measurement Principle: Ultrasonic Transit-time Difference Correlation Principle Communication: 4~20mA, OCT
Accuracy: ±1.0%R Power Supply: AC: 85-265V
Transmitter Weight: 0.5kg Cable Length: STD: 5m
Battery: 14 Hours Function: Data Logger
High Light:

rechargeable 5M Ultrasonic Flow Meter

,

DN15 OCT Ultrasonic Flow Meter

,

DN15 OCT Transit Time Flow Meter

AC85-265V 5M Transit Time Ultrasonic Flow Meter
 

Transit Time Ultrasonic Flow Meter Application:

It is well suited for applications ranging from flow into water treatment plants, storm and sanitary sewer systems, and effluent from water resource recovery, to industrial discharge and irrigation channels.

 
Transit Time Ultrasonic Flow Meter Advantage

  • No shutdown, no drilling and no pressure drop
  • pipe size from DN15mm to DN6000mm
  • Displays instantaneous flow, accumulated flow (positive, negative and net), velocity, working status etc.
  • Built-in rechargeable Ni-MH rechargeable battery,
  • provide over 20 hours of continuous operation.
 

Ultrasonic Water Flow Meter​ Specifications: Transmitter

ItemsPerformance & Parameter

 

 

Host

 

PrincipleTransit- time ultrasonic flowmeter
Accuracy±1%
Display2X20 character LCD with backlight, support the language of Chinese, English and Italy

Signal

Output

1 way 4~20mA output, electric resistance 0~ 1K, accuracy 0. 1%(optional)

1 way OCT pulse output(Pulse width 6~1000ms, default is 200ms)

1 way Relay output

 

Signal

Input

3 way 4~20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level
Connect the temperature transducer Pt100, can finish the heat/energy measurement

Data

Interface

Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS
Special CableTwisted-pair cable, generally, the length under 50 meters ; Select the RS485, transmission distance can over 1000m

Pipe

Installation

Condition

Pipe

Material

Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed

Pipe

Diameter

DN20~6000mm

Straight

Pipe

Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump

Measuring

Medium

Mediumwater,sea water ,alcohol,Acid and alkali,waste water,beer,all kinds of oil Single liquid can transmit sound wave.
Temperature-30~160℃
TurbidityNo more than 10000ppm and less bubble
Flowrate0~±7m/s,Forward and backward measurement
Work environmentProtection gradeHost:IP67;flow sensor:IP68
temperatureHost:-20~60℃;flow sensor:-30~ 160℃
HumidityHost: 85%RH; Flow sensor:can measure under water, water depth^2m (tansducer sealed glue)
Power SupplyDC8~36V or AC85~264V

Power

Consumption

1.5W
Dimension132*150*85mm(host)
 

Digital Handheld Ultrasonic Water Flow Meter​ Features
 

1..14 hours battery (rechargeable), back-lit 4 lines display.
2.. Data logger function.
3.. Lightweight and easily transportable in box.
4.. Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking.
5.. Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃.
6.. Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.
 


 

The digital handheld ultrasonic water flow meter TF1100-CH works on the principle of transit-time, and the host size is 212*100*36mm. When measuring on site, you can manually operate to obtain data.

It is suitable for measuring relatively pure liquid in a closed full pipe, and is widely used in water supply and drainage, air conditioning and heating, building energy saving, petrochemical, metallurgy and other fields

 
Specifications: Transducer
 

Degree of protectionIP65 according to EN60529.(IP67 or IP68 Upon request)
Pipe diameter range20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L
Suited Liquid TemperatureStd. Temp.: -35℃~85℃ for short periods up to 120℃
High Temp.: -35℃~200℃ for short periods up to 250℃
Transducer SizeType S 48(h)*28(w)*28(d)mm
Type M 60(h)*34(w)*33(d)mm
Type L 80(h)*40(w)*42(d)mm
Material of transducerAluminum for standard temp. sensor, and peek for high temp. sensor
Cable LengthStd: 5m


Data sheet download TF1100-CH transit-time handheld ultrasonic flowmet...
Manual Download TF1100-CH transit-time handheld flowmeter Manual.p...
Dimensional Sketches
Transmitter:                                                                                                                   
Transducer:
Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter 0                        Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter 1
 

Packing & Delivery

 

With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support. With years of export experience along with excellent quality, advanced services and competitive prices, Lanry has won numerous customers' trust and support.
 
Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter 2Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter 3Rechargeable DN15 OCT 5M Transit Time Ultrasonic Flow Meter 4

Delivery

Clamp On Handheld Ultrasonic Flow Meter TF1100-CH for water and chilled water application
Standard meter: 3-7 days
Special meter: pls contact us
Express, by air, by sea can be optional.

 

Contact Details
Lanry Instruments (Shanghai) Co., Ltd.

Contact Person: Ms. Tracy Xu

Tel: 86-021-67618991

Fax: 86-021-67801625

Send your inquiry directly to us (0 / 3000)